- 00090010:
- GEIIS
- 00091012:
- MSA=
- 00190010:
- GEMS_ACQU_01
- 00191023:
- MjAuNjI1MDAwIA==
- 00191027:
- MC42MDAwMDA=
- 00191039:
- AgA=
- 0019106A:
- BgA=
- 00430010:
- GEMS_PARM_01
- 00431027:
- MC41MTY6MSA=
- 0043102B:
- BAAAAAAAAAA=
- 00431065:
- AAA=
- 00431067:
- AAA=
- 00450010:
- GEMS_HELIOS_01
- 00451013:
- EQA=
- 00451021:
- AAA=
- 00451022:
- AAA=
- 0045103B:
- None
- 00530010:
- GEHC_CT_ADVAPP_001
- 00531040:
- QVI1MA==
- 00531061:
- MCA=
- 00531063:
- Q09STkVSRklSU1RQSVhFTA==
- 09030010:
- GEIIS PACS
- 09031010:
- AAA=
- 09031011:
- AAA=
- 09031012:
- AAA=
- 09050010:
- GEIIS
- 09051030:
- VGhlIFdvbGxvbmdvbmcgSG9zcGl0YWwg
- 7FD10010:
- R0VJSVMg
- 7FD11030:
- AwAAAA==
- 7FD11040:
- QAAAAIAAAAAAAQAAAAIAAA==
- 7FD11050:
- QAAAAIAAAAAAAQAAAAIAAA==
- 7FD11060:
- wBAAAIArAACskgAASOYBAA==
- AcquisitionDate:
- 20220609
- AcquisitionNumber:
- 1
- AcquisitionTime:
- 143059.600
- BitsAllocated:
- 16
- BitsStored:
- 16
- BodyPartExamined:
- HEAD
- Columns:
- 512
- ContentDate:
- 20220609
- ContentTime:
- 143642
- ContributingEquipmentSequence:
- [{'Manufacturer': 'GE MEDICAL SYSTEMS', 'InstitutionName': 'Wollongong Hospital', 'StationName': 'miwct210', 'ManufacturerModelName': 'Volume Viewer', 'SoftwareVersions': ['10.5.30.n'], 'PurposeOfReferenceCodeSequence': [{'CodeValue': '109102', 'CodingSchemeDesignator': 'DCM', 'CodeMeaning': 'Processing Equipment'}]}, {'Manufacturer': 'GE MEDICAL SYSTEMS', 'InstitutionName': 'Wollongong Hospital', 'StationName': 'CT_ROOM1', 'ManufacturerModelName': 'Revolution CT', 'SoftwareVersions': ['revo_ct_21b.32'], 'PurposeOfReferenceCodeSequence': [{'CodeValue': '109101', 'CodingSchemeDesignator': 'DCM', 'CodeMeaning': 'Acquisition Equipment'}]}]
- ConvolutionKernel:
- ['STANDARD']
- DataCollectionDiameter:
- 320.000000
- DistanceSourceToDetector:
- 1097.610000
- DistanceSourceToPatient:
- 625.610000
- ExposureTime:
- 1095
- FileMetaInformationGroupLength:
- 192
- FileMetaInformationVersion:
- AAE=
- FilterType:
- MEDIUM FILTER
- FocalSpots:
- ['0.700000', '1.000000 ']
- FrameOfReferenceUID:
- 1.2.840.113619.2.416.85713151503463352076122202828572560648
- GeneratorPower:
- 7200
- HighBit:
- 15
- ImageOrientationPatient:
- ['0.9996511936', '0.004374145996', '0.02604614384', '0.00437414553', '0.9451496005', '-0.3266084492']
- ImagePositionPatient:
- ['-116.5056915', '-147.1279297', '168.8311768 ']
- ImageType:
- ['DERIVED', 'SECONDARY', 'REFORMATTED', 'AVERAGE']
- ImplementationClassUID:
- 1.2.276.0.7230010.3.0.3.6.9
- ImplementationVersionName:
- OFFIS_DCMTK_369
- InstanceCreationDate:
- 20220609
- InstanceCreationTime:
- 143642
- InstanceNumber:
- 9
- InstitutionName:
- Wollongong Hospital
- KVP:
- 120
- Manufacturer:
- GE MEDICAL SYSTEMS
- ManufacturerModelName:
- Revolution CT
- MediaStorageSOPClassUID:
- 1.2.840.10008.5.1.4.1.1.2
- MediaStorageSOPInstanceUID:
- 1.2.840.113619.2.80.459708988.14347.1654749402.10
- Modality:
- CT
- OperatorsName:
- ['ctuser']
- OtherPatientIDs:
- None
- PatientAddress:
- 15 Rainbird Rd,, CD:-2526 Kembla Grange
- PatientPosition:
- HFS
- PerformingPhysicianName:
- ['^']
- PhotometricInterpretation:
- MONOCHROME2
- PixelRepresentation:
- 1
- PixelSpacing:
- ['0.4882812202', '0.4882812202 ']
- PositionReferenceIndicator:
- SN
- ProtocolName:
- 1.4 Brain - FastStroke CTA
- RequestAttributesSequence:
- [{'RequestedProcedureID': '1801321'}]
- RescaleIntercept:
- -1024
- RescaleSlope:
- 1
- RotationDirection:
- CW
- Rows:
- 512
- SOPClassUID:
- 1.2.840.10008.5.1.4.1.1.2
- SOPInstanceUID:
- 1.2.840.113619.2.80.459708988.14347.1654749402.10
- SamplesPerPixel:
- 1
- ScanOptions:
- ['HELICAL MODE']
- SecondaryCaptureDeviceManufacturer:
- GE MEDICAL SYSTEMS
- SecondaryCaptureDeviceManufacturerModelName:
- Volume Viewer
- SecondaryCaptureDeviceSoftwareVersions:
- ['10.5.30.n']
- SeriesDate:
- 20220609
- SeriesDescription:
- Axial
- SeriesInstanceUID:
- 1.2.840.113619.2.80.459708988.14347.1654749400.1.4.1
- SeriesNumber:
- 303
- SeriesTime:
- 143640
- SliceLocation:
- 131.2608948
- SliceThickness:
- 5
- SoftwareVersions:
- ['revo_ct_21b.32']
- SpecificCharacterSet:
- ['ISO_IR 100']
- StationName:
- CT_ROOM1
- TableHeight:
- 189.500000
- TemporalPositionIndex:
- None
- TransferSyntaxUID:
- 1.2.840.10008.1.2.4.70
- WindowCenter:
- ['40']
- WindowWidth:
- ['100 ']
- XRayTubeCurrent:
- 259