Series: ISMAY^BRUCE MALCOLM MR 20211009

Image set: 14f49fc4a7f8c903fd1c9bec3d7e5d13

# Description Protocol Mod Slices Thickness Contrast kVp
201 Axial 1.14 CT Perfusion Telestroke - Complete study CT 42 5 120
tags
00090010:
GEIIS
00091012:
1
00190010:
GEMS_ACQU_01
00191023:
10.625000
00191027:
0.800000
00191039:
2
0019106A:
6
00430010:
GEMS_PARM_01
00431027:
0.531:1
0043102B:
[4, 0, 1, 0]
00431065:
0
00431067:
0
00450010:
GEMS_HELIOS_01
00451013:
0
00451021:
1
00451022:
0
0045103B:
None
00530010:
GEHC_CT_ADVAPP_001
00531020:
0
00531040:
SS50
00531061:
0
00531063:
CORNERFIRSTPIXEL
09030010:
GEIIS PACS
09031010:
0
09031011:
0
09031012:
0
09050010:
GEIIS
09051030:
Shoalhaven Dist.Mem. Hospital
7FD10010:
GEIIS
7FD11030:
3
7FD11040:
[64, 128, 256, 512]
7FD11050:
[64, 128, 256, 512]
7FD11060:
[4036, 9996, 33432, 108288]
AcquisitionDate:
20211009
AcquisitionNumber:
1
AcquisitionTime:
070835.767052
BitsAllocated:
16
BitsStored:
16
Columns:
512
ContentDate:
20211009
ContentTime:
071942
ContributingEquipmentSequence:
[{'Manufacturer': 'GE MEDICAL SYSTEMS', 'InstitutionName': 'Shoalhaven District Hospital', 'StationName': 'minct211', 'ManufacturerModelName': 'Volume Viewer', 'SoftwareVersions': ['10.5.62'], 'PurposeOfReferenceCodeSequence': [{'CodeValue': '109102', 'CodingSchemeDesignator': 'DCM', 'CodeMeaning': 'Processing Equipment'}]}, {'Manufacturer': 'GE MEDICAL SYSTEMS', 'InstitutionName': 'Shoalhaven District Hospital', 'StationName': 'SDMH_CT_Rm_1', 'ManufacturerModelName': 'Optima CT660', 'DeviceSerialNumber': '*', 'SoftwareVersions': ['cj3_6m3a_qr.11'], 'PurposeOfReferenceCodeSequence': [{'CodeValue': '109101', 'CodingSchemeDesignator': 'DCM', 'CodeMeaning': 'Acquisition Equipment'}]}]
ConvolutionKernel:
['STANDARD']
DataCollectionDiameter:
320.000000
DeviceSerialNumber:
*
DistanceSourceToDetector:
949.147000
DistanceSourceToPatient:
541.000000
ExposureTime:
1460
FileMetaInformationGroupLength:
194
FileMetaInformationVersion:
AAE=
FilterType:
HEAD FILTER
FocalSpots:
['0.700000']
FrameOfReferenceUID:
1.2.840.113619.2.438.3.621466569.608.1633649752.49.7015.1
GeneratorPower:
24000
HighBit:
15
ImageOrientationPatient:
['1', '0', '0', '0', '0.9974913001', '-0.07078966498 ']
ImagePositionPatient:
['-109.7850266', '-112.6548843', '3.546573639 ']
ImageType:
['DERIVED', 'SECONDARY', 'REFORMATTED', 'AVERAGE']
ImplementationClassUID:
1.2.276.0.7230010.3.0.3.6.9
ImplementationVersionName:
OFFIS_DCMTK_369
InstanceCreationDate:
20211009
InstanceCreationTime:
071942
InstanceNumber:
9
InstitutionName:
Shoalhaven District Hospital
KVP:
120
Manufacturer:
GE MEDICAL SYSTEMS
ManufacturerModelName:
Optima CT660
MediaStorageSOPClassUID:
1.2.840.10008.5.1.4.1.1.2
MediaStorageSOPInstanceUID:
1.2.840.113619.2.80.1966174792.23085.1633724382.10
Modality:
CT
OperatorsName:
['ctuser']
OtherPatientIDs:
None
PatientAddress:
32 York St,, CD:-2539 Cunjurong Point
PatientPosition:
HFS
PerformingPhysicianName:
['^']
PhotometricInterpretation:
MONOCHROME2
PixelRepresentation:
1
PixelSpacing:
['0.4296875', '0.4296875 ']
PositionReferenceIndicator:
SN
ProtocolName:
1.14 CT Perfusion Telestroke - Complete study
RequestAttributesSequence:
[{'RequestedProcedureID': '1647363'}]
RescaleIntercept:
-1024
RescaleSlope:
1
RotationDirection:
CW
Rows:
512
SOPClassUID:
1.2.840.10008.5.1.4.1.1.2
SOPInstanceUID:
1.2.840.113619.2.80.1966174792.23085.1633724382.10
SamplesPerPixel:
1
ScanOptions:
['HELICAL MODE']
SecondaryCaptureDeviceManufacturer:
GE MEDICAL SYSTEMS
SecondaryCaptureDeviceManufacturerModelName:
Volume Viewer
SecondaryCaptureDeviceSoftwareVersions:
['10.5.62']
SeriesDate:
20211009
SeriesDescription:
Axial
SeriesInstanceUID:
1.2.840.113619.2.80.1966174792.23085.1633724379.1.4.1
SeriesNumber:
201
SeriesTime:
071939
SliceLocation:
-4.240289688
SliceThickness:
5
SoftwareVersions:
['cj3_6m3a_qr.11']
SpecificCharacterSet:
['ISO_IR 100']
StationName:
SDMH_CT_Rm_1
TableHeight:
206.000000
TemporalPositionIndex:
None
TransferSyntaxUID:
1.2.840.10008.1.2.4.70
WindowCenter:
['35']
WindowWidth:
['95']
XRayTubeCurrent:
194